Deye product-family image. Check the model number for the exact item.
Deye Hybrid Inverters · Three phase · High voltage
Deye 10kW High Voltage Hybrid Inverter
SUN-10K-SG01HP3-AU-AM2 Three phase
The SUN-10K-SG01HP3-AU-AM2 is Everest’s 10 kW three-phase hybrid inverter option for a high-voltage battery system.
Business, farm or larger site? See the 29.9–80 kW commercial rangeBatteries and other system components sold separately.
- Owned and operated by Aussie electricians
- Advice from the electricians who install Deye
Place your order and we email a secure payment link, normally within one business day. Nothing is charged until you pay the link. Free delivery included. Installation is separate. Online Deye Price Beat Guarantee — seen it cheaper? Tell us before you order.
Want a licensed electrician with Deye experience to install this? Click to connect with a Deye installer
What will it run at once during a blackout?
In a blackout, your solar and battery are the only supply, so the inverter’s kW is the most your backup circuits can draw at once. The battery’s kWh is how long that lasts. Pick what you would run together to compare the sizes.
- 5 kWCovers it · 1.95 kW spareSmallest that covers it
- 6 kWCovers it · 2.95 kW spareSmallest that covers it
- 8 kWCovers it · 4.95 kW spareSmallest that covers it
- 10 kWCovers it · 6.95 kW spareSmallest that covers itThis page
- 12 kWCovers it · 8.95 kW spareSmallest that covers it
- 15 kWCovers it · 11.95 kW spareSmallest that covers it
- 20 kWCovers it · 16.95 kW spareSmallest that covers it
- 25 kWCovers it · 21.95 kW spareSmallest that covers it
This 10 kW model runs all of it with 6.95 kW to spare. The 5 kW model is the smallest that does.
A 10 kWh battery runs all of this for about 2 h 45 min on its own.
Fridge, air-con and pump motors draw extra for a moment as they start. Deye rates this model for 1.5 times its output for 10 seconds, which covers that. A kettle, oven or heater draws its full power for minutes, so it counts in full.
An estimate, not a guarantee. Appliance figures are typical running power. Only circuits wired to the inverter’s backup port run in a blackout; while the grid is on, it supplies anything above the inverter’s rating. The battery estimate assumes about 85% of its nominal kWh reaches your appliances. Each battery also has its own output limit, so we check the battery against what you want to run.
Three ways to set it up
A hybrid inverter runs your solar, battery, home and grid together. Here is how it fits, depending on what you have now. We’ll confirm the right one for your home.
New solar and battery
Solar, battery and grid in one
Your panels connect straight to the inverter’s own solar inputs. It runs your home from solar, stores the surplus in the battery and sends what is left to the grid.
- Solar powers your home first
- The battery covers your evenings
- Six time-of-use periods for cheaper power
You’ll need a Deye high-voltage battery stack. Your installer adds a CT or meter at the main switch so the inverter can see what your home uses.
Existing solar
Add a battery to the solar you have
AC coupling connects your existing solar inverter to the hybrid, so its surplus solar charges the battery. Keep your panels and your current inverter.
- Keep your panels and current inverter
- Surplus solar charges the battery
- New panels can go on the hybrid too
We check your existing inverter, switchboard and export limit before you order.
Blackouts and generators
Backup, off-grid and generator
If the grid goes down, the inverter keeps your backup circuits running from solar and battery. A generator can charge the battery when the sun can’t.
- Backup circuits stay on
- Battery charging from a generator
- Off-grid, and up to 10 in parallel
Your electrician moves the circuits you want kept on to the inverter’s backup port. It is not the whole house unless the system is designed that way.
How it runs your day
Six time-of-use periods
Set when the battery charges from the grid or a generator, and when it powers your home.
On-grid or off-grid
Runs with the grid, or on its own from solar, battery and generator.
AC coupling
Brings an existing solar inverter into the system.
Generator charging
Stores energy from a generator in the battery.
Deye’s datasheet for this range, in Documents, lists these. Your installer sets them up on the inverter.
Built around your energy needs
The SUN-10K-SG01HP3-AU-AM2 is Everest’s 10 kW three-phase hybrid inverter option for a high-voltage battery system. It brings solar generation and battery storage together, so a system can be designed around when your household needs electricity. Choose this model by its power rating, supply phase and battery voltage class. Battery capacity is a separate choice: a 5 kW inverter does not automatically mean a 5 kWh battery.

Battery
Built for a high-voltage battery
It runs a Deye high-voltage battery stack at 160–700 V: modules in series with a control box, so the same power flows at a much lower current than a 48 V battery.
- 160–700 VBattery range
- LithiumBattery type
- 6Time-of-use periods

Solar
Two solar inputs
Two MPPT trackers run separate strings of panels, so roofs facing different ways each work at their best. Deye lists up to 15,000 W of solar input for this model, and up to 20,000 W of panels connected. Panel strings must also suit its voltage and current limits.
- 2MPPT trackers
- 15 kWSolar input
- 180 VStart-up voltage

At home
Built to live on a wall
An IP65 enclosure with a noise rating of ≤55 dB. 30.5 kg and 408 × 638 × 237 mm, so it sits beside the battery indoors, or outdoors out of direct sun. Check and change settings on its screen, or in the Deye Cloud app through a Deye data logger.
- IP65Enclosure
- ≤55 dBNoise
- 30.5 kg408 × 638 × 237 mm
Protection built in
Surge protection
Type II on the solar (DC) and grid (AC) sides.
Anti-islanding
Disconnects from the grid when the grid goes down, as Australian grid rules require.
Residual current detection
Watches for current leaking to earth.
Insulation monitoring
Checks the solar wiring’s insulation to earth.
Overload and short circuit
Output over-current, over-voltage and short-circuit protection.
Reverse polarity
Protects against solar strings connected the wrong way round.
From the protection list in Deye’s datasheet for this range. Arc fault protection (AFCI) is listed as optional, so ask us whether your unit has it. The datasheet lists AS/NZS 4777.2, the Australian standard for grid-connected inverters.
8, 10 or 12 kW?
The sizes either side of this one, from Deye’s datasheets.
| Feature | 8 kWSUN-8K-SG01HP3-AU-AM2 | 10 kWSUN-10K-SG01HP3-AU-AM2 · this page | 12 kWSUN-12K-SG01HP3-AU-AM2 |
|---|---|---|---|
| Price | incl. GST | $2,372.00 incl. GST | incl. GST |
| Rated output | 8 kW | 10 kW | 12 kW |
| Solar input | 12,000 W | 15,000 W | 18,000 W |
| Panels you can connect | 16,000 W | 20,000 W | 24,000 W |
| Solar trackers (MPPT) | 2 (1 + 1 strings) | 2 (1 + 1 strings) | 2 (2 + 1 strings) |
| Grid-to-home passthrough | 40 A | 40 A | 80 A |
| Off-grid peak | 1.5 × rated power for 10 seconds | 1.5 × rated power for 10 seconds | 1.5 × rated power for 10 seconds |
| Size and weight | 408 × 638 × 237 mm, 30.5 kg | 408 × 638 × 237 mm, 30.5 kg | 408 × 638 × 237 mm, 30.5 kg |
| Datasheet | Names this exact model | Names this exact model | Names this exact model |
High-voltage battery parts
A high-voltage stack is designed as one: BOS-G modules in series, one control box and a rack. We size it to this inverter’s battery range with you.

- 5.12 kWh nominal
- 19-inch BOS-G rack
- IP20

- IP20


Your installer confirms the final battery, quantity and layout for your site.
Deye hybrids installed in Australia
Larger Deye high-voltage hybrids with BOS-G batteries, from Deye Australia’s project cases.



Photos: Deye Australia project cases, from Deye’s March 2026 Australian brochure.
What your electrician will do
- Check your supply and switchboardSingle or three phase, room for the breakers, and your network’s export and connection rules.
- Mount the inverterOn a solid wall, out of direct sun, with the clearances in Deye’s manual.
- Connect solar, battery and CTSolar strings to the MPPT inputs, the battery with its communication cable, and a CT or meter at the main switch.
- Wire the grid and backup circuitsThe grid to the grid port and the circuits you want kept on to the backup port, each with its own breaker.
- Commission itSet the grid settings your network requires, the battery type and the work mode, then pair a data logger for the app.
SUN-10K-SG01HP3-AU-AM2 specifications
Specifications below refer to the manufacturer document shown on this page. Check the document revision and exact model before specifying a system.
| Everest SKU | SUN-10K-SG01HP3-AU-AM2 |
|---|---|
| Product type | Wall mount |
| Power supply | Three phase |
| Catalogue power rating | 10 kW |
| Battery system | High voltage |
| Maximum PV input power | 15000 W |
|---|---|
| Maximum PV access power | 20000 W |
| Maximum PV input voltage | 1000 V |
| MPPT voltage range | 150–850 V |
| MPPTs / strings per MPPT | 2 / 1 + 1 |
| Maximum PV operating current | 20 + 20 A |
| Maximum PV short-circuit current | 30 + 30 A |
| Start-up voltage | 180 V |
| Battery voltage range | 160–700 V |
|---|
| Rated AC active power | 9999 W |
|---|---|
| Rated AC current | 14.5 A |
| Continuous AC passthrough | 40 A |
| Off-grid peak power | 1.5 × rated power for 10 seconds |
| Maximum conversion efficiency | 97.6% |
| Enclosure rating | IP65 |
|---|---|
| Cabinet dimensions (W × H × D) | 408 × 638 × 237 mm; excludes connectors and brackets |
| Weight | 30.5 kg |
| Noise | ≤55 dB |
| Connection suitability | Installer and network approval required |
Product selection and installation must be checked for your site.
SUN-10K-SG01HP3-AU-AM2 spec sheets and documents
Deye’s datasheet for this model. Read it here, or download a copy.
The document will load when you reach this section.
Questions about this inverter?
Tell us about your supply, your solar and the battery you have in mind. The model number travels with your enquiry.
What size inverter do I need?
Size it to what your home runs at once, and to your solar. 10 kW is the most it supplies at once from solar and battery; the check on this page compares the sizes. Solar is the other limit: Deye lists up to 15,000 W of solar input for this model and up to 20,000 W of panels connected. We confirm the size against your switchboard, your network’s rules and your battery.
What is the difference between kW and kWh?
10 kW is the inverter’s power: how much it supplies at once. A battery’s storage is measured in kWh: how long it lasts. For example, a 10 kWh battery runs a 2 kW load for about four hours.
Can I add a battery to the solar I already have?
Yes. AC coupling connects your existing solar inverter to this hybrid, so its surplus solar can charge the battery. You keep your panels and inverter, and new panels can go on its own solar inputs. We check your existing inverter, switchboard and export limit first.
Will it keep my power on in a blackout?
It keeps the circuits wired to its backup port running from solar and battery. Your electrician chooses those circuits, so it is not the whole house unless the system is designed that way. It supplies up to 10 kW at once, with a peak of 1.5 times its rating for 10 seconds while motors start.
Can it charge the battery from the grid at cheaper times?
Yes. Six time-of-use periods let your installer set when the battery charges from the grid or a generator, and when it powers your home.
Which batteries work with it?
Deye high-voltage lithium batteries, built as a stack: BOS-G modules in series with a control box and a rack. The stack’s voltage must sit inside this inverter’s 160–700 V battery range, so we design it with you.
What does high voltage mean here?
The battery modules connect in series, so the stack runs at 160–700 V instead of the 40–60 V of a low-voltage battery. It needs a Deye high-voltage battery stack; low-voltage batteries do not connect to it.
Do I need three-phase power for this?
Yes. It connects to a three-phase supply. Deye lists 100% unbalanced output, so each phase can carry a different load.
Can I add another inverter later?
Yes. Deye lists up to 10 of these in parallel, on-grid or off-grid, for more power. A parallel system is set up as one, so plan it with us.
Can I connect a generator?
Yes. Deye lists generator charging for this range, so a generator can charge the battery through the inverter.
Can it be installed outside?
Yes. It is rated IP65. Your installer picks a spot out of direct sun, with room for airflow.
How do I check on it?
On its screen, or in the Deye Cloud app through a Deye data logger. Ask us which logger suits your inverter.
Is this the Australian model?
Yes. Deye’s datasheet lists SUN-10K-SG01HP3-AU-AM2 by this exact model number, with AS/NZS 4777.2, the Australian standard for grid-connected inverters.
Does this include batteries?
This page is for the inverter. Batteries, bases, cabling and installation are quoted separately unless Everest explicitly includes them in your system quotation.
Can I order this on its own?
Yes. Add it to your cart, continue to checkout and place your order. We confirm stock and email you a secure payment link, normally within one business day. Nothing is charged until you pay the link. Delivery is free on inverter or battery orders and quoted for parts-only orders. Any installation is arranged separately.
Can Everest help with compatibility?
Yes. Include the model numbers of your existing inverter, batteries and any other system parts in your enquiry. Matching a brand or power rating alone does not confirm compatibility.
More Deye Hybrid Inverters
View the range
Wall mountDeye 8kW High Voltage Hybrid InverterSUN-8K-SG01HP3-AU-AM2
Wall mountDeye 12kW High Voltage Hybrid InverterSUN-12K-SG01HP3-AU-AM2
Wall mountDeye 6kW High Voltage Hybrid InverterSUN-6K-SG01HP3-AU-AM2
Wall mountDeye 5kW High Voltage Hybrid InverterSUN-5K-SG01HP3-AU-AM2